BotRescueBotRescue

Error 5

Roborock Error 5: Main Brush Jammed

Applies to: Roborock. Meanings can vary by model — trust the voice alert on your unit.

What does Error 5 mean?

Roborock Error 5 means the main brush cannot turn — usually hair or debris in the brush, end bearings, or installation slots. Official support also recommends a Carpet-mode test after cleaning.

How do I fix Error 5?

  1. Flip the robot, remove the main-brush cover, and take out the brush.
  2. Clear hair from the brush, both ends, bearings, and the two installation slots.
  3. Reinstall until the cover locks.
  4. Run a short clean with Carpet mode enabled.
  5. If Error 5 returns after a thorough clean, request main-brush motor or gearbox repair.

Still stuck?

Run free diagnosis for a guided path, or book a Brisbane meetup if DIY is not enough.