GFCI Trip
Maytronics Dolphin: Ground Fault — Cable or Supply
Applies to: Maytronics Dolphin. Meanings can vary by model — trust the voice alert on your unit.
What causes it?
A GFCI (RCD) trip when running a Dolphin usually means the outlet, power supply, floating blue cable, or robot motor path has a ground fault. Maytronics requires a direct GFCI outlet — no extension cords or power strips.
How to fix it
- Reset the GFCI and confirm the outlet works with another device.
- Unplug any extension cord or surge strip; plug the power supply directly into a working GFCI outlet.
- Inspect the blue floating cable and black mains cord for cuts, kinks, or frays — replace a damaged cable.
- Disconnect the blue cable and power the supply alone: if it stays on, the fault is in the cable or robot (dealer / BotRescue); if it still trips or will not power, the supply likely needs replacement.