Will not charge / poor runtime
Where to look: underside / top sensors as described in the steps.
Robot will not wake, battery % does not rise on the dock, or runtime collapses after a short clean. Start with contacts and dock power (Error 13 path) before assuming a dead pack.
_Legacy Roborock brand hub guide — steps match official Error tables for S7/S8/Q-class robots._
What you might notice
- Will not power on
- Battery % not rising while docked
- Very short runtime after a full charge
- Dock indicator behaviour looks wrong
Can I DIY this?
Medium DIY (~15-30 min). Follow the steps once. Stop if you hit sealed motors or a lithium pack — use meetup / mail-in.
What you need
- Soft cloth
- Alcohol wipe or soft eraser
- Flashlight
Do this
- Clean charging contacts on the dock and robot with a soft cloth lightly moistened with alcohol, or a soft eraser; dry fully.
- Confirm dock power: with the robot off the dock the indicator should be solid on; with the robot docked it should turn off (per your dock style).
- Seat the power cable firmly in the dock, try another wall outlet, then unplug the dock for about 2 minutes and retry.
- Seat the robot centred so both pads touch and leave it to charge.
- If it still will not charge after clean contacts and verified dock power, request battery or dock repair — do not open the lithium pack yourself.
Parts (only if cleaning fails)
- Dock power cable
- Battery pack (service — lithium)
Official references
- https://support.roborock.com/hc/en-us/articles/360035369312-What-should-I-do-when-error-13-occurs
- https://support.roborock.com/hc/en-us/articles/36835084556953-What-should-I-do-when-error-13-occurs
Still stuck?
Parts for this fix
Prefer buying the part and DIY when safe — round-trip postage often rivals a new machine. Ship docks only if we ask.
- Dock power cableSearch Amazon AU →
- Battery pack (service — lithium)Search Amazon AU →
As an Amazon Associate, BotRescue may earn from qualifying purchases. Prices and stock are on Amazon AU. · campaign guide-roborock